Au Bon Pain
FAILTuesday, June 3, 2008 at 4:37 PM
Violations Cited
20-4-703.11
Food Contact Surfaces Clean
Provide proper sanitizing reading to sanitizing Solution at 3 compartment sink.
Why This Matters
INVISIBLE KILLERS: Bacteria survive on 'clean-looking' surfaces for days. Inadequate sanitization caused Salmonella outbreak affecting 1,500 people via ice cream. Cutting boards can harbor 200 times more fecal bacteria than toilet seats. E. coli survives 1-4 hours on surfaces. Norovirus survives 2 weeks. One contaminated slicer infected 300 people with Listeria.
Code Requirements
SANITIZATION MANDATORY: Chemical sanitizers: Chlorine 50-100 ppm, Quaternary Ammonium 200-400 ppm, Iodine 12.5-25 ppm; Hot water: 171°F for 30 seconds by immersion; Contact time: minimum 7-30 seconds depending on sanitizer; Test concentration EVERY 2 hours; Change solution when visibly soiled; ALL food contact surfaces must be sanitized: After each use with different foods; When switching raw to ready-to-eat; Every 4 hours in continuous use.
Corrective Actions
IMMEDIATE: Set up proper sanitizer at ALL stations; Test and adjust concentration NOW; Re-sanitize ALL food contact surfaces; Obtain test strips immediately; Post sanitizer concentration chart; Train staff on test strip use; Create sanitization log; Change solutions every 2 hours minimum
05-4-302.12
Food Thermometers Provided
Provide food thermometers for all food prep personal.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section . Implement proper food safety procedures. Train all staff. Document corrective actions taken.
17-4-204.112/.115
Equipment Thermometers
Provide internal thermometers for Salad refrigerators in front service area. Throughout establishment.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section . Implement proper equipment procedures. Train all staff. Document corrective actions taken.
23-4-602.13
Non-Food Contact Surfaces Clean
Properly clean grease buildup in ovens.
Why This Matters
INDIRECT CONTAMINATION: Dirty surfaces attract pests, harbor bacteria, and contaminate via contact or air movement. Dust from dirty shelves contains allergens affecting 32 million Americans. Grease accumulation creates slip hazards causing 25% of restaurant injuries.
Code Requirements
Non-food contact surfaces must be cleaned at frequency to prevent: Soil accumulation; Pest attraction; Contamination of food/food contact surfaces. Includes: Equipment exteriors; Shelving; Walls and ceilings; Light fixtures; Ventilation systems.
Corrective Actions
Deep clean all non-food contact surfaces; Create cleaning schedule with daily, weekly, monthly tasks; Assign cleaning zones to staff; Use degreaser for grease accumulation; Clean from top to bottom; Maintain cleaning log
33-5-501.13-.17
Adequate Number Frequency Vermin Proof
Properly clean and coverall waste receptacles
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section . Implement proper food safety procedures. Train all staff. Document corrective actions taken.
37-6-501.11-.12
Improper Maintenance of Walls/Ceilings
Properly resurface stained ceiling areas above and next to oven.
Why This Matters
OVERHEAD CONTAMINATION: Peeling paint and debris fall into food. Condensation on ceilings drips bacteria onto prep surfaces. Studies found ceiling tiles harbor Bacillus cereus spores. Restaurant ceiling collapse contaminated food service for 200 guests.
Code Requirements
Walls/ceilings must be: Smooth and washable in food areas; Light-colored for easy soil detection; Free of holes, cracks, peeling paint; Sealed at all joints and attachments; Clean and free of grease, dust, cobwebs; Non-absorbent in areas subject to moisture.
Corrective Actions
Repair all holes within 14 days; Repaint with washable paint; Replace damaged ceiling tiles; Seal all penetrations; Clean walls and ceilings monthly; Fix any leaks immediately; Install FRP panels in splash zones
38-6-202.11
Fixture's not properly shielded
Provide missing light shield for lights in walk. In freezer. And in rear food prep area.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section . Implement proper food safety procedures. Train all staff. Document corrective actions taken.
38-6-303.11
Inadequate Lighting
Provide adequate lighting # Walk. In refrigerator.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section . Implement proper food safety procedures. Train all staff. Document corrective actions taken.