Caffe Dello Sport
FAILWednesday, June 17, 2020 at 6:07 PM
Violations Cited
590.004/4-501.114-P
Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)
Low temp dishwasher unable to sanitize. Repair. PIC call for repair will whick to paper until repair is finish.
Why This Matters
INEFFECTIVE SANITIZATION: Below 50ppm chlorine or 200ppm quat, bacteria survive on 'clean' dishes. Above 200ppm chlorine leaves toxic residue causing chemical burns, nausea. 70% of restaurant outbreaks linked to improper sanitization.
Code Requirements
Maintain sanitizer at: Chlorine 50-100ppm, Quaternary Ammonium 200-400ppm, Iodine 12.5-25ppm. Test every 2 hours with test strips. Change solution when cloudy/dirty. Train all staff on mixing procedures.
590.004/4-302.14-PF
Sanitizing Solutions Testing Devices (Pf)
No test for low temp dishwasher.Provide to ensure proper dilution of sanitizer.
Why This Matters
This violation supports conditions that may lead to foodborne illness
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper cleaning & sanitization procedures. Train all staff. Document corrective actions taken.
590.004/4-601.11-PF
(A) Equipment Food-Contact Surfaces Nonfood-Contact Surfaces and Utensils (Pf)
Brown rust like substance in ice machine . EMPTY CLEAN AND SANITIZE before refilling.
Why This Matters
Improper equipment maintenance can harbor bacteria and contaminate food
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper equipment procedures. Train all staff. Document corrective actions taken.
590.004/4-204.112-C
Temperature Measuring Devices-Functionality (C)
Some refrigeration units without thermometers. Provide to ensure proper cold holding.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.
590.004/4-602.13-C
Nonfood Contact Surfaces (C)
Defrost and clean of one freezer chest in basement.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.
590.006/6-301.14-C
Handwashing Signage (C)
No handwashing signage at Handsink at service counter . Provide proper signage
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.006. Implement proper personal hygiene procedures. Train all staff. Document corrective actions taken.