🚨 Recent Restaurant Closures 🚨

CVS No. 117

FAIL

Thursday, May 15, 2025 at 4:45 PM

Address
1921 CENTRE ST
West Roxbury, MA 02132
Category
RF
Violations
6 total
⚠️ 1 critical
⚠ 1 major
Facility History
32 inspections
9 failures

Violations Cited

⚠️ CRITICAL 590.003/3-501.16-P
✓ Corrected

(A)(2) and (B) Time/Temperature Control for Safety Food Hot and Cold Holding (P)

Naked Juice drinks in retail reach in at 73F. Unit was not working. PIC removed and will have unit repaired. All other drinks are shelf stable.

Why This Matters

RAPID BACTERIAL GROWTH: At 50°F, E. coli doubles every 30 minutes. At 70°F, it doubles every 20 minutes. After 4 hours above 41°F, bacteria can reach dangerous levels causing severe illness. Common result: 24-72 hours of diarrhea, vomiting, fever, potential hospitalization.

Code Requirements

Immediately discard foods held above 41°F for over 4 hours. Rapidly cool foods above 41°F if less than 2 hours. Check ALL cooler temps every 2 hours with calibrated thermometer. Repair/adjust refrigeration immediately. Never store food in non-refrigerated areas.

Mass. Code: 105 CMR 590.003 | FDA Code: Section 3
⚠ MAJOR 590.004/4-301.11-PF

Cooling Heating and Holding Capacities-Equipment (Pf)

Retail reach in for drinks reading 69F and 73F inside. PIC has a call to have repaired. 5-15-25 Unit is still not working. Parts have been ordered.

Why This Matters

Improper equipment maintenance can harbor bacteria and contaminate food

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper equipment procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.004/4-202.16-C
✓ Corrected

Nonfood-Contact Surfaces (C)

Black wire shelves in reach in for milk will need to be cleaned from dry milk debris.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.004/4-204.112-C

Temperature Measuring Devices-Functionality (C)

PIC should provide a back up thermometer to the reach in unit so that temperatures can be checked.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.006/6-201.11-C
✓ Corrected

Floors Walls and Ceilings-Cleanability (C)

The floor under wire shelves in walk in for drink visibly soiled. Please clean to remove.

Why This Matters

Poor facility maintenance can harbor pests and prevent proper cleaning

Code Requirements

Smooth, non-porous surfaces; Properly sloped to drains; No gaps or cracks; Maintained clean

Mass. Code: 105 CMR 590.006 | FDA Code: Section 6
• MINOR 590.006/6-501.11-C

Repairing-Premises Structures Attachments and Fixtures-Methods (C)

The gasket on the glass door for the drink unit that was not working properly will need to be replaced. 5-15-25 Gasket is on order.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.006. Implement proper food safety procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.006 | FDA Code: Section 6
View Facility Profile →
Data sourced directly from Boston Inspectional Services Department