Dunkin Gate C Baggage Claim
FAILWednesday, February 19, 2025 at 4:00 PM
Violations Cited
590.004/4-501.114-P
Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)
Three Bay Sink- Sanitizing Bay plug does not block water properly can not mantained filled with sanitizer. Repair.
Why This Matters
INEFFECTIVE SANITIZATION: Below 50ppm chlorine or 200ppm quat, bacteria survive on 'clean' dishes. Above 200ppm chlorine leaves toxic residue causing chemical burns, nausea. 70% of restaurant outbreaks linked to improper sanitization.
Code Requirements
Maintain sanitizer at: Chlorine 50-100ppm, Quaternary Ammonium 200-400ppm, Iodine 12.5-25ppm. Test every 2 hours with test strips. Change solution when cloudy/dirty. Train all staff on mixing procedures.
590.005/5-205.15-C
System Maintained in Good Repair (C)
Drain at the floor for liquid discharge from serving line machine filled with water/blocked.Employ removing water with vacuum cleaner. Repair.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.005. Implement proper food safety procedures. Train all staff. Document corrective actions taken.