🚨 Recent Restaurant Closures 🚨

Honeygrow

FAIL

Tuesday, December 12, 2023 at 6:51 PM

Address
100 NORTHERN AV
Boston, MA 02210
Category
FS
Violations
1 total
⚠️ 1 critical
Facility History
33 inspections
13 failures

Violations Cited

⚠️ CRITICAL 590.004/4-501.114-P

Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)

The low temperature dish machine is reading an error message that rinse temperature is too low @ 105F. Make all necessary repairs. Unit is testing at 50PPM with test strip.

Why This Matters

INEFFECTIVE SANITIZATION: Below 50ppm chlorine or 200ppm quat, bacteria survive on 'clean' dishes. Above 200ppm chlorine leaves toxic residue causing chemical burns, nausea. 70% of restaurant outbreaks linked to improper sanitization.

Code Requirements

Maintain sanitizer at: Chlorine 50-100ppm, Quaternary Ammonium 200-400ppm, Iodine 12.5-25ppm. Test every 2 hours with test strips. Change solution when cloudy/dirty. Train all staff on mixing procedures.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
View Facility Profile →
Data sourced directly from Boston Inspectional Services Department