Kings Bowl Seaport
PASSWednesday, August 10, 2022 at 5:47 PM
Violations Cited
590.004/4-501.114-P
Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)
Low temp dish machine not registering chlorine sanitizer when tested. Alternative means to sanitize on site in other low temp unit and high temp unit in kitchen if needed.
Why This Matters
INEFFECTIVE SANITIZATION: Below 50ppm chlorine or 200ppm quat, bacteria survive on 'clean' dishes. Above 200ppm chlorine leaves toxic residue causing chemical burns, nausea. 70% of restaurant outbreaks linked to improper sanitization.
Code Requirements
Maintain sanitizer at: Chlorine 50-100ppm, Quaternary Ammonium 200-400ppm, Iodine 12.5-25ppm. Test every 2 hours with test strips. Change solution when cloudy/dirty. Train all staff on mixing procedures.
590.004/4-302.13-PF
Temperature Measuring Devices Manual and Mechanical Warewashing (Pf)
No irreversible indicator for dish machine. Provide.
Why This Matters
This violation supports conditions that may lead to foodborne illness
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.