Navarrete Restaurant
FAILWednesday, August 24, 2022 at 4:58 PM
Violations Cited
590.003/3-501.16-P1
(A)(1) Time/Temperature Control for Safety Food Hot and Cold Holding (P)
Chicken in back room 110F and pork 90F. PIC will reheat. Fried pork at front counter 114F. Reheat and keep sliding doors closed. Baked chicken in large hot holding cabinet at 120F. PIC will need to reheat and provide door for unit to keep the heat in.
Why This Matters
RAPID BACTERIAL GROWTH: At 50°F, E. coli doubles every 30 minutes. At 70°F, it doubles every 20 minutes. After 4 hours above 41°F, bacteria can reach dangerous levels causing severe illness. Common result: 24-72 hours of diarrhea, vomiting, fever, potential hospitalization.
Code Requirements
Immediately discard foods held above 41°F for over 4 hours. Rapidly cool foods above 41°F if less than 2 hours. Check ALL cooler temps every 2 hours with calibrated thermometer. Repair/adjust refrigeration immediately. Never store food in non-refrigerated areas.
590.003/3-501.17-PF
Ready-To-Eat Time/Temperature Control for Safety Food Date Marking (Pf)
PIC will need to date mark cold cuts in walk in as discussed.
Why This Matters
This violation supports conditions that may lead to foodborne illness
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.003. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.
590.005/5-203.11-PF
Handwashing Sinks-Numbers and Capacities (Pf)
PIC is cutting cold cuts and making pizza dough in basement with no hand sink. PIC will need to provide a hand sink and be approved to be prep in the basement.
Why This Matters
CONTAMINATION CYCLE: Using handwash sink for dishes spreads grease and food particles, making hand cleaning ineffective. Staff avoid dirty sinks, reducing handwashing by 60%. Creates breeding ground for bacteria at the most critical hygiene point.
Code Requirements
STOP all non-handwashing use immediately. Handwash sinks for HANDS ONLY. Clean and sanitize sink completely. Post signage 'HANDWASHING ONLY'. Designate separate sinks for food prep and dishwashing. Retrain all staff.
590.003/3-305.11-C
Food Storage-Preventing Contamination from the Premises (C)
PIC will need to discontinue to store product on the floor in walk in. Must be 6 inches off the floor.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.003. Implement proper food storage procedures. Train all staff. Document corrective actions taken.
590.004/4-202.16-C
Nonfood-Contact Surfaces (C)
Clean shelves in basement. Soiled.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.
590.004/4-202.18-C
Ventilation Hood Systems Filters (C)
Clean hood filters and have hood cleaned and new sticker provided. Hood sticker expired April 2022
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.
590.004/4-501.11-C
Good Repair and Proper Adjustment-Equipment (C)
Large standing fan in kitchen did not have a front cover. PIC will need to provide so that its safe to use.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper equipment procedures. Train all staff. Document corrective actions taken.
590.004/4-903.12-C
Prohibitions (C)
Discontinue to store napkins on the floor in the basement.
Why This Matters
This violation affects overall sanitation and food safety
Code Requirements
Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.
590.006/6-201.11-C
Floors Walls and Ceilings-Cleanability (C)
PIC will need to clean the basement floors and walls. Clean under shelves and organize all shelves.
Why This Matters
Poor facility maintenance can harbor pests and prevent proper cleaning
Code Requirements
Smooth, non-porous surfaces; Properly sloped to drains; No gaps or cracks; Maintained clean
590.006/6-201.16-C
Wall and Ceiling Coverings and Coatings (C)
Replace stained ceiling tiles in kitchen area.
Why This Matters
Poor facility maintenance can harbor pests and prevent proper cleaning
Code Requirements
Smooth, washable surfaces; No holes or damage; Light-colored in food areas; Clean condition