🚨 Recent Restaurant Closures 🚨

Shaking Seafood

PASS

Wednesday, January 19, 2022 at 7:12 PM

Address
1616 DORCHESTER AVE
Dorchester, MA 02122
Category
FT
Violations
4 total
⚠ 1 major
Facility History
17 inspections
7 failures

Violations Cited

⚠ MAJOR 590.004/4-302.12-PF
✓ Corrected

Food Temperature Measuring Devices (Pf)

At the time of the inspection there were no food thermometers available. Provide.

Why This Matters

TEMPERATURE ABUSE: Without thermometers, 73% of foods are held at unsafe temperatures. Bacteria double every 20 minutes between 41-135°F. Undercooked ground beef (not reaching 155°F) causes E. coli outbreaks affecting hundreds.

Code Requirements

Provide calibrated probe thermometers immediately: One per cook station minimum, Range -40°F to 200°F, Accurate to ±2°F, Calibrate daily in ice water (32°F). Check temps every 2 hours for holding, always for cooking.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.003/3-304.14-C
✓ Corrected

Wiping Cloths Use Limitation (C)

Soiled wiping cloths observed being left out on counter tops. Discontinue and provide a proper sanitizing solution.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.003. Implement proper food safety procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.003 | FDA Code: Section 3
• MINOR 590.004/4-202.16-C
✓ Corrected

Nonfood-Contact Surfaces (C)

What appears to be a drainage tube directed into the wash bay of the 3 compartment sink. Discontinue and and redirect drainage tube to ensure proper disposal.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper food safety procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.004/4-204.112-C
✓ Corrected

Temperature Measuring Devices-Functionality (C)

Equipment therometer in Coke cooler near the rice cooking station damaged. Replace.

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
View Facility Profile →