🚨 Recent Restaurant Closures 🚨

Three Clover

PASS W/ CONDITIONS

Monday, November 14, 2011 at 7:09 PM

Address
401 W BROADWAY
South Boston, MA 02127
Category
FT
Violations
4 total
Facility History
18 inspections
10 failures

Violations Cited

• MINOR 15-4-202.16
✓ Corrected

Non-Food Contact Surfaces

tin foil lining ansul system piping remove

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section . Implement proper food safety procedures. Train all staff. Document corrective actions taken.

FDA Code: Section 15.4.202
• MINOR 36-6-201.11

Floors Designed Constructed Installed

floor with missing floor tiles replace

Why This Matters

Poor facility maintenance can harbor pests and prevent proper cleaning

Code Requirements

Smooth, non-porous surfaces; Properly sloped to drains; No gaps or cracks; Maintained clean

FDA Code: Section 36.6.201
• MINOR 37-6-201.11
✓ Corrected

Walls/Ceilings Designed Constructed Installed

1) no hood cleaning Inspection Sticker supply

Why This Matters

Poor facility maintenance can harbor pests and prevent proper cleaning

Code Requirements

Smooth, washable surfaces; No holes or damage; Light-colored in food areas; Clean condition

FDA Code: Section 37.6.201
• MINOR 37-6-501.11-.12
✓ Corrected

Improper Maintenance of Walls/Ceilings

hood and vents with grease build up clean to remove

Why This Matters

OVERHEAD CONTAMINATION: Peeling paint and debris fall into food. Condensation on ceilings drips bacteria onto prep surfaces. Studies found ceiling tiles harbor Bacillus cereus spores. Restaurant ceiling collapse contaminated food service for 200 guests.

Code Requirements

Walls/ceilings must be: Smooth and washable in food areas; Light-colored for easy soil detection; Free of holes, cracks, peeling paint; Sealed at all joints and attachments; Clean and free of grease, dust, cobwebs; Non-absorbent in areas subject to moisture.

Corrective Actions

Repair all holes within 14 days; Repaint with washable paint; Replace damaged ceiling tiles; Seal all penetrations; Clean walls and ceilings monthly; Fix any leaks immediately; Install FRP panels in splash zones

Mass. Code: 105 CMR 590.006(B) | FDA Code: Section 6-501.11, 6-501.12