🚨 Recent Restaurant Closures 🚨

Audubon

FAIL

Monday, March 31, 2025 at 6:42 PM

Address
838 BEACON ST
Boston, MA 02215
Category
FS
Violations
4 total
⚠️ 1 critical
⚠ 2 major
Facility History
27 inspections
13 failures

Violations Cited

⚠️ CRITICAL 590.004/4-501.114-P
✓ Corrected

Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)

Quats sanitizer being used from an automated dispenser at the 3 bay sink is testing at 0ppm Sanitizer shall be manually set up until proper repairs are made Ecolab contacted at the time of the inspection

Why This Matters

INEFFECTIVE SANITIZATION: Below 50ppm chlorine or 200ppm quat, bacteria survive on 'clean' dishes. Above 200ppm chlorine leaves toxic residue causing chemical burns, nausea. 70% of restaurant outbreaks linked to improper sanitization.

Code Requirements

Maintain sanitizer at: Chlorine 50-100ppm, Quaternary Ammonium 200-400ppm, Iodine 12.5-25ppm. Test every 2 hours with test strips. Change solution when cloudy/dirty. Train all staff on mixing procedures.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
⚠ MAJOR 590.004/4-501.112-PF
✓ Corrected

Mechanical Warewashing Equipment Hot Water Sanitization Temperatures (Pf)

High temperature dishwasher in the lower level with a rinse temperature of 160F Rinse shall be maintained at 180F-194F Ecolab contacted for repairs at the time of the inspection- Establishment not yet open for business for the day

Why This Matters

Improper equipment maintenance can harbor bacteria and contaminate food

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper temperature control procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
⚠ MAJOR 590.004/4-601.11-PF
✓ Corrected

(A) Equipment Food-Contact Surfaces Nonfood-Contact Surfaces and Utensils (Pf)

Internal panel of ice machine with mold like buildup- Clean properly

Why This Matters

Improper equipment maintenance can harbor bacteria and contaminate food

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper equipment procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
• MINOR 590.004/4-501.11-C

Good Repair and Proper Adjustment-Equipment (C)

Rinse gauge on the high temperature dishwasher was repaired by Ecolab and is not properly fuctioning An irreversible thermometer indicated that the dish machine is properly working- Rinse temperature of 183F Ecolab contacted at the time of the inspection to come properly repair the unit

Why This Matters

This violation affects overall sanitation and food safety

Code Requirements

Immediate correction required. Follow health code section 105 CMR 590.004. Implement proper equipment procedures. Train all staff. Document corrective actions taken.

Mass. Code: 105 CMR 590.004 | FDA Code: Section 4
View Facility Profile →